TM 10-4320-344-24
2.15.3 Battery Box Assembly Maintenance, Model 609-C.
This task covers:
2.15.3.1 Removal
2 .
15 . 3 . 2 I n s t a l l a t i on
INITIAL SETUP
Tools
General Safety Instructions
General Mechanics Automotive
To prevent rolling or sliding, do not work
Tool Kit, Appendix B, Section
on equipment that is not securely
III, Item 1
s t a b i l i z e d.
Material/Parts
Fumes from battery acid may cause explosion,
which could result in personal injury. Keep
Gloves, Appendix C, Item 11
sparks and open flame away from battery.
Tags, Appendix C, Item 31
Lock Washers (TM 10-4320-344-24P)
B a t t e r y e l e c t r o l y t e c o n a i n s s u l f u r i c a c i d,
which can cause severe burns. If
Equipment Conditions
electrolyte should contact skin or clothing,
rinse immediately with clean water and seek
Pumping station shut down, TM
medical attention.
10-4320-344-10.
Do not work on equipment without following
standard shop safety precautions.
2.15.3.1 Removal.
a .
Open battery access door assembly (Figure 2-39, 1) on pumping assembly (2).
Fumes from battery acid may cause explosion, which could result in personal
injury. Keep sparks and open flame away from battery.
b .
Pull up and out on two locking handles (3) and open battery cover (4).
Remove negative battery cable first. Failure to obey this warning may result
in death or personnel injury.
c .
Tag positive (+), negative (-), and connector battery cable assemblies (6).
Loosen four battery terminals (5) and remove battery cable assemblies (6) from
storage batteries (7 and 8).
2-111