a .
Remove three nuts (Figure 2-37, 1), lock washers (2), and screws (3). Discard
lock washers (2).
b .
Pull service light assembly (4) away from pumping assembly (5).
c .
Disconnect service light connector (6) from main wiring harness connector (7).
d.
Remove service light assembly (4) from pumping assembly (5).
2.15.1.2 Repair.
a .
Replace defective light bulb (10) by removing retaining ring (8), lens (9),
and bulb (10) from service light housing (11).
b .
Replace all defective components.
2.15.1.3 Installation.
a .
If light bulb (10) was defective, install new bulb (10), lens (9), and
retaining ring (8) in service light housing (11).
b .
Insert service light connector (6) into pumping assembly (5) and connect
harness connector (7) and service light connector (6).
c .
Insert service light assembly (4) into pumping assembly (5) and secure with
three screws (3), new lock washers (2), and nuts (1).
2-107