TM 10-4320-344-102.5.2.2 AutomaticMode.(Continued)Figure 2-26. Shutdown Requirements for Model 609-C.2.5.3 Operation of Model US636HCCD-1.The pumping assembly is capable of two modes ofoperation,electric manual and electric automatic.Use electric manual mode forstartup.Electric automatic mode may be used for sustained operation afterstartup.2.5.3.1 Electric Manual Mode.Before starting pumping assembly, make sure that thepump has been primed (paragraph 2.4.1 or 2.4.2).Refer to Figure 2-27 and startand operate pumping assembly as follows:a.Perform "Before" PMCS (Table 2-12).b .Turn MANUAL THROTTLE INCREASE knob (6) counterclockwise to IDLE position.c .Set MODE SWITCH (5) to MANUAL position.d.Pull out START/STOP knob (3).WARNINGTo avoid hearing loss, hearing protection must be worn by personnelstanding within 50 feet of operating pumping assembly.CAUTIONTo prevent damage to starter, do not crank engine for more than 30 secondsand allow 3 minutes between start attempts.e.Push in START button (4) and ENGINE OIL PRESSURE BYPASS switch (8) at sametime for no more than 30 seconds.When engine starts, release START button( 4 ) .If engine fails to start, wait 3 minutes between start attempts.2-104