TM 10-4320-344-10
Figure 2-28.
Model WS636HCCD-1 Controls Used for Electric Automatic Operation.
CAUTION
To prevent damage to engine, DO NOT shut down engine suddenly from
full-load running.
e .
Shut down pumping assembly as follows:
(1) Turn MANUAL THROTTLE INCREASE knob (3) counterclockwise to IDLE
p o s i t i o n.
Let engine idle for 2 or 3 minutes.
(2) Push in START/STOP knob (1). Engine will shut down.
f .
Perform "After" PMCS (Table 2-12) .
2-107