TM 10-4320-315-24
2-44. MAINTENANCE OF V-BELT TENSIONER ASSEMBLY
This task covers:
a.
Remove
b.
Install
INITIAL SETUP
Tools
Equipment Conditions
General Mechanics Tool Kit
Pumping assembly is shutdown (refer to TM 10-4320-
(Item 1, Appendix B)
315-10).
Battery assembly is disconnected (para. 2-16).
Materials/Parts
O-ring
(TM 10-4320-315-24P)
a.
REMOVE. (Figure 2-31)
NOTE
V-Belt warning switch is not utilized with control panel on this unit.
(1)
Pull plug connector (1) from V-belt warning switch (4).
(2)
Remove bolts (2), nut (3), and V-belt warning switch (4).
(3)
Remove bolts (5), flat washers (6), and V-belt tensioner assembly (7).
(4)
Remove O-ring (8) from V-belt tensioner assembly (7).
b.
INSTALL.
(1)
Install O-ring (8) on V-belt tensioner assembly (7).
(2)
Install V-belt tensioner assembly (7) with flat washers (6) and bolts (5).
(3)
Install V-belt warning switch (4) with nut (3) and bolt (2).
(4)
Push plug connector (1) onto V-belt warning switch (4).
2-82