TM 10-4320-310-145-14.INSPECT/REPLACE/REPAIR FRAME ASSEMBLY (FRAME, RAILS AND SHOCK MOUNTS)(Continued)CLEANING/INSPECTION:.Dry cleaning solvent P-D-680 (safety or Stoddard's Solvent) Is potentiallydangerous. Avoid repeated and prolonged breathing of vapors and skincontact with the liquid. Do not use near open flame, arcing equipment, orother ignition sources. Always wear eye protection and protective clothing.The flash point of P-D-680 Is 100°F to 138°F (38°C to 59°C).Death or serious Injury could occur if compressed air Is directed against theskin. Do not use compressed air for cleaning or drying unless the pressureis/has been reduced to 30 psi (2.06 bar) or less. When working withcompressed air always use chip guards, eye protection, and other personalequipment.1Using dry cleaning solvent and stiff-bristled brush, clean all parts thoroughly. Dry with compressed air.2Inspect left mounting bracket (5), right mounting bracket (8) and frame (6) for dents, rust, corrosion, structuraldamage, or warpage. If damaged or warped, repair.3Inspect shock mounts (7) for brittleness and deterioration.REPAIR:If frame has broken welds, chip away loose material before reworking welds.INSTALLATION:1Install shock mounts (7) in frame (6) brackets.2Install two hexagon head cap screws (1), flat washers (4), new lock washers (3) and hexagon nuts (2) and secureright mounting bracket (8) to frame (6). Tighten hexagon nuts (2) securely.3Install two hexagon head cap screws (1), flat washers (4), new lock washers (3) and hexagon nuts (2) and secureleft mounting bracket (5) to frame (6). Tighten hexagon nuts (2) securely.5-38
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business