TM 10-4320-310-14
5-14.
INSPECT/REPLACE/REPAIR
FRAME
ASSEMBLY
(FRAME,
RAILS
AND
SHOCK
MOUNTS)
(Continued)
CLEANING/INSPECTION:
.
Dry cleaning solvent P-D-680 (safety or Stoddard's Solvent) Is potentially
dangerous. Avoid repeated and prolonged breathing of vapors and skin
contact with the liquid. Do not use near open flame, arcing equipment, or
other ignition sources. Always wear eye protection and protective clothing.
The flash point of P-D-680 Is 100°F to 138°F (38°C to 59°C).
Death or serious Injury could occur if compressed air Is directed against the
skin. Do not use compressed air for cleaning or drying unless the pressure
is/has been reduced to 30 psi (2.06 bar) or less. When working with
compressed air always use chip guards, eye protection, and other personal
equipment.
1
Using dry cleaning solvent and stiff-bristled brush, clean all parts thoroughly. Dry with compressed air.
2
Inspect left mounting bracket (5), right mounting bracket (8) and frame (6) for dents, rust, corrosion, structural
damage, or warpage. If damaged or warped, repair.
3
Inspect shock mounts (7) for brittleness and deterioration.
REPAIR:
If frame has broken welds, chip away loose material before reworking welds.
INSTALLATION:
1
Install shock mounts (7) in frame (6) brackets.
2
Install two hexagon head cap screws (1), flat washers (4), new lock washers (3) and hexagon nuts (2) and secure
right mounting bracket (8) to frame (6). Tighten hexagon nuts (2) securely.
3
Install two hexagon head cap screws (1), flat washers (4), new lock washers (3) and hexagon nuts (2) and secure
left mounting bracket (5) to frame (6). Tighten hexagon nuts (2) securely.
5-38