TM 10-4320-307-24
3-21
ALTERNATOR REPAIR (CONT).
5.
Remove four screws and lockwashers (20) securing voltage regulator (21) and gasket (22) to slip ring end housing
(15).
6.
Remove three locknuts (23); tag and remove AC terminals and stator (24).
7.
Tag and remove remaining terminals.
8.
Remove nuts (25) from output terminals (26).
9.
Remove screws (27), insulation bushings (28), and washers (29) from rectifier assemblies (30) and remove rectifier
assembly and regulator holder (31).
10. Remove four screws (32) securing cover plate (33) and O-ring (34) to slip ring end housing (15).
11. Remove two screws (35) securing brush holder adapter (36) to slip ring end housing (15).
12. Cut terminals off ends of brush holder adapter (36) and remove adapter.
13. Remove rubber grommet (37) from hole.
14. Remove two screws (38) securing connector assembly (39) to regulator holder (31).
3-55