TM 10-4320-307-24
3-8
PUMP ASSEMBLY REPAIR/REPLACE (CONT).
INSTALLATION:
Death or serious injury could occur if unauthorized or unnecessary personnel are in the hoisting
area. Permit only personnel actually engaged in the hoisting operation to be near the unit and
hoisting equipment. All instructions for the hoisting operations must come from one authorized
person.
Injury to personnel or damage to equipment could occur from improper hoisting. Hoist the load
slowly to avoid tearing out lifting bail assembly, slipping slings, or load shift. Do not jerk the
load or swing it from side-to-side when hoisting. This places additional stress on hoisting
components which can cause failure and loss of load. Be sure hoisting equipment is on solid
footing and is suitable for the size of the load. Watch boom angle and overhead clearance when
hoisting.
1.
Position a suitable lifting device and slings over
pump assembly (1). Attach slings around assembly
and put tension on slings. Make sure pump
assembly is properly supported.
2.
Lift and remove pump assembly (1) from blocks on
work platform.
3.
Lower pump assembly (1) carefully so that it aligns
with mounting holes on skid (2). Remove lifting
device.
4.
Install four bolts (3) and torque to 369 ft-lb (500 Nm)
and secure pump to skid (2).
5.
Install piping and vent assembly in accordance with
paragraph 3-9.
6.
Install flexible coupling in accordance with paragraph
3-7.
7.
Fill pump assembly in accordance with paragraph 2-
25.
8.
Install suction and discharge assembly in accordance
with paragraph 2-56.
3-20