TM10-4320-226-142.8.1.2 On Model 350 PAWN perform the following procedures for cold starting.NOTEOn Model 350 PAWN the cold start system is a fully-automatic engine starting fluidsystem designed to spray a controlled amount of starting fluid into the air intake systemof an engine during and immediately after cranking.Do not puncture or mishandle quick start kit container. Container contains ether-basedmixture that is extremely flammable and toxic. It can be harmful or fatal if swallowed.Avoid contact with skin or eyes or breathing fumes. Failure to obey this warning mayresult in injury or death.a.The engine start cartridge(1, figure 2-10.1) is secured with clamp(2) in bracket(3) and mounted on the engine.To determine if the cartridge is serviceable or requires replacing refer to procedures in paragraph 4.10.3.1.Do not operate the 350 GPM Pumping Assembly without grounding.Do not operate equipment in enclosed area unless exhaust gases are piped to outsideand adequate ventilation is provided. Avoid inhalation of exhaust fumes.Failure to obey warnings may result in personnel injury or death.Do not stand within 50 feet of operating equipment without ear protection,Failure toobey this warning may result in hearing loss.C A U T I O N Do not operate starter motor for more than 10 seconds, damage to starter can resultb.If, the engine start cartridge(l) is determined serviceable, depress the start button(4) on control panel.c.Refer to operating procedures (paragraph 2.5), but allow the engine to warm up a full five minutes beforeaccelerating to full speed RPM.Change22-29
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business