TM 10-4320-226-14d.e.f.g.*h.i.j.2.7.2Remove quick release pins (1 and 2,figure 2-9) from tongue and extend tongueextension (3) to full length.Insert quick release pin (1 and 2) and secure tongue.Release pintle (4) and connect pumping assembly to towing vehicle (5).Attach and secure 350 GPM Pumping Assembly to towing vehicle.Remove pins (6 and 7) and push upward on trailer support legs (8) until holesalign with mounting holes for pins (6 and 7).Reinstall pins (6 and 7) to secure trailer support legs (8).Do not tow 350 GPM Pumping Assembly more that 20 miles perhour (mph).Failure to obey this caution could result in equipmentdamage.Tow 350 GPM Pumping Assembly to new location at worksite.PreparationforMovementtoNewWorksite.Perform the following to move 350 GPMPumping Assembly to another worksite.a.b.c.d.e.f.If operating, perform shutdown procedures provided in paragraph 2.5.2.Disconnect suction hose (1, figure 2-8) from coupler half (2) and connectquick disconnect plug (3) to coupler half (2).Disconnect discharge hose (4) from coupler half (5) and connect quickdisconnect cap (6) to coupler half (5).Attach lifting equipment to 350 GPM Pumping Assembly and lift equipmentflatbed trailer.Secure the 350 GPM Pumping Assembly on trailer or vehicle.Transport 350 GPM Pumping Assembly to new worksite location.on2-26
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business