Figure 4-8. Filter Separator (Front).b. Cleaning and Inspection.WARNINGDrycleanlng solvent, P-D-689, used to clean parts is potentially dangerousto personneL and property. Avoid repeated and proLonged skin contact. Donot use near open frame or excessive heat. Flash point of solvent is 100°Fto 138°F (38°C to 59°C).(1) Clean the filter/separator in drycleaning solvent (item 1, Appendix E).(2) Dry thoroughly.(3) Inspect the filter/separator for distortion, broken welds, dents, and other damage.4-22TM5-4930-230-13