2-4. ASSEMBLY AND PREPARATION FOR USE
a. The pumping assembly comes fully assembled, ready for use after attaching the suction and discharge hoses.
b. The operator must know how to perform every operation of which the unit is capable. The following
paragraphs contain instructions on starting and stopping the unit, operation of the pump assembly, and coordinating the
basic motions to perform the specific tasks for which the equipment is designed. Since nearly every job presents a
different problem, the operator may have to vary given procedures to fit an individual job.
2-5. INITIAL ADJUSTMENTS AND DAILY CHECKS
a. Loosen studs on control panel cover door. Lift door.
b. Position controls as follows:
(1) MANUAL THROTTLE CONTROL (1) pushed in.
(2) Engine START/STOP switch (2) down at STOP position.
c. Perform all category B preventive maintenance checks and services (PMCS) listed in Table 2-2. Report any
problems to organizational maintenance.
d. If pumping assembly has not been operated for one week, perform all category B and W PMCS listed in
Table 2-2. Report any problems to organizational maintenance.
e. If pumping assembly has not been operated for more than a month, perform all PMCS listed in Table 2-2.
Report any problems to organizational maintenance.
2-53