INTERVALITEMNO.ITEM TO BE INSPECTEDPROCEDUREEquipment isNot Ready/AvailableTM 5-4320-306-10Table 2-2. Preventive Maintenance Checks and Services - ContinuedB - Before OperationA - After OperationD - During OperationW - WeeklyBDAW24Engine Shutdown Valve (Electrical).Check for loose or missing electrical connector (1).Check for frayed insulation or other damage to wires(2) running to electrical connector.25Ether Start KitDuring coldweather operation,Check that ether cylinder (1) is firmly in place. The valve does notThe cylinder should be finger tight in valve (2).Release ether.Inspect cylinder (1) and valve (2) for dents, corrosion,or other damage.Inspect the valve assembly(2) for corrosion or otherdamage. Verify valveoperation by pulling knob(3) for 3 seconds or less.If the valve operates freelybut no ether is released,replace the cylinder(1) and test the valve again.Inspect hose (4) for leaks orcracks. The hose should besecured to fitting (5) at bothends.TM 5-4320-306-102-37