8. PUMP FAILS TO PRIME - TM-5-4320-302-14_95
Section I. REPAIR PARTS, SPECIAL TOOLS, TMDE, AND SUPPORT EQUIPMENT
TM-5-4320-302-14 Forward Area Water Point Supply System (FAWPSS) Model WP55100 NSN 4320-01-168-1629 and Model 9095-91 NSN 4320-01-338-3305 Manual
Page Navigation
83
84
85
86
87
88
89
90
91
92
93
TM 5-4320-302-14
Table 3-1. Operator/Crew Troubleshooting-Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
9. PUMP FAILS TO DELIVER CAPACITY
Check for excessive suction lift.
Refer to operator's instruction plate.
10. NOISY PUMP OPERATION
Notify organizational maintenance.
11. LOW DISCHARGE PRESSURE
Step 1. Check for low engine speed.
Adjust throttle to increase engine speed to 2800 rpm.
Step 2. Check suction line for loose connections.
Tighten loose connections.
3-13/(3-14 blank)