TM 5-4320-302-14
5-19.
ALTERNATOR (CONT)
Location/Item
Action
Remarks
CLEANING/INSPECTION
WARNING
Dry cleaning solvent is flammable and potentially
dangerous to people and property. Do not use near
open flame, sparks, excessive heat, or on hot
surfaces. Flash point of P-D-680 solvent is 100° to
138°F (38° to 59°C). Use solvent in a well-ventilated
area, and avoid inhaling fumes. If repeatedly
exposed to fumes, seek fresh air and immediate
medical help. Avoid prolonged exposure of skin to
solvent. Wash exposed skin immediately and
thoroughly.
Death
or
severe
injury
might
result
when
compressed air is used to blow dirt from skin or
clothing. Air entering body openings is extremely
dangerous. Compressed air used for cleaning shall
not exceed 100 psi (690 kPa). Use goggles or face
shield for eye protection. Do not direct airstream
against skin.
CAUTION
Do not use solvent to clean any materials made of
plastic. Solvent could dissolve plastic.
18. All alternator
Clean with P-D-680 dry cleaning solvent and dry
components
with compressed air.
except plastic
parts
19. Terminal
Inspect for cracks, separations, stripped threads, and
assemblies
other damage. Replace as necessary.
20. Drive bearing
Inspect for rust, cracks, bearing bore wear, distortion,
and bearing
damaged threads, and other obvious damage. Remove
support
any burrs with MIL-S-17243 surfacing stone. Replace
either unit if not repairable.
5-68