TM 5-4320-302-145-18.STARTER MOTOR (CONT)Location/ItemActionRemarksd.Position capsule over armature shaft and alinewith screw holes in commutator bearing support.e.Install commutator bearing support screws andtighten securely.35. Relaya.Position on drive bearing and aline mountingholes.b.Install relay countersunk screws and tightensecurely.c.Position wire (exciter winding to relay) on terminalstud on relay.d.Install spring lockwashers and hex nuts on terminalson relay and tighten securely.e.Install clamp and relay screw and tighten securely.FINAL TESTCAUTIONUnder no-load conditions the starter will exceed safeRPM's.36. StarterRetest assembled starter as in step 1. Connect starterin series with a fully charged 12-volt battery and connecta remote starting switch as shown. Energize starter bymomentarily depressing switch; observe whether pinionmoves forward and begins rotating at a high rate ofspeed. If it does not, consult the symptom chart in step1 and proceed accordingly.5-59