TM 5-4320-300-145-20. PUMP ASSEMBLY (CONT)Location/ItemActionRemarksWARNINGMake sure that hoists and other lifting equipment are in good repair and ofsufficient capacity to safely handle loads without injury to personnel ordamage to equipment. Securely attach lifting equipment. Before lifting, besure load is balanced.2.DischargeRemove mounting nuts. Attach lift equipmentelbowand remove elbow. Remove and discard gasket.3.Pipe plugsRemove. Allow fluid to drain into suitableand drain plugcontainer.4.Suction andRemove in accordance with paragraph 5-19.discharge gagevalves, lines,and fittings5.Pump bodyLoosen mounting bolts. Attach lift equipmentand bearingand remove mounting bolts. Lift pump body andhousingbearing housing from frame assembly and placeon a suitable platform.INSTALLATIONWARNINGMake sure that hoists and other lifting equipment are in good repair and ofsufficient capacity to safely handle loads without injury to personnel ordamage to equipment. Securely attach lifting equipment. Before lifting,be sure load is balanced.6.Pump bodyAttach liftand bearingequipment.housingLift pumpbody andbearinghousinginto posi-tion overthe frameassemblyand lowerinto place.Installmountingbolts andtightensecurely.5-80