TM 5-4320-300-14
5-20. PUMP ASSEMBLY (CONT)
Location/Item
Action
Remarks
WARNING
Make sure that hoists and other lifting equipment are in good repair and of
sufficient capacity to safely handle loads without injury to personnel or
damage to equipment. Securely attach lifting equipment. Before lifting, be
sure load is balanced.
2.
Discharge
Remove mounting nuts. Attach lift equipment
elbow
and remove elbow. Remove and discard gasket.
3.
Pipe plugs
Remove. Allow fluid to drain into suitable
and drain plug
container.
4.
Suction and
Remove in accordance with paragraph 5-19.
discharge gage
valves, lines,
and fittings
5.
Pump body
Loosen mounting bolts. Attach lift equipment
and bearing
and remove mounting bolts. Lift pump body and
housing
bearing housing from frame assembly and place
on a suitable platform.
INSTALLATION
WARNING
Make sure that hoists and other lifting equipment are in good repair and of
sufficient capacity to safely handle loads without injury to personnel or
damage to equipment. Securely attach lifting equipment. Before lifting,
be sure load is balanced.
6.
Pump body
Attach lift
and bearing
equipment.
housing
Lift pump
body and
bearing
housing
into posi-
tion over
the frame
assembly
and lower
into place.
Install
mounting
bolts and
tighten
securely.
5-80