TM 5-4320-300-14
Section VI. PREPARATION FOR STORAGE OR SHIPMENT
4-49.
GENERAL
This section provides instructions for preparing the centrifugal pump unit for short term and intermediate storage or
shipment.
4-50.
ADMINISTRATIVE STORAGE
Administrative storage shall be in accordance with AR 750-1.
4-51.
SHORT TERM STORAGE (30 days or less)
NOTE
When centrifugal pump unit is taken out of service, take special precautions to protect the interior
and exterior of the unit from rust accumulation and corrosion.
a. Lower the back of the frame assembly.
WARNING
Severe burns, illness, or death may result if personnel fail to handle diesel
fuel properly. Observe the following precautions:
·
Do not inhale vapor.
·
Do not refuel near open flame, sparks, or excessive heat.'
·
Be certain fuel lines and connections are secure.
·
Do not overfill fuel tank.
·
Work in a well-ventilated area.
b. Fill fuel tank with VV-F-800 diesel fuel oil. Connect centrifugal pump unit to a water supply. Operate the engine for
2 minutes at 1200 rpm and no load.
NOTE
Do not drain the fuel system after this run. Remove water supply after this run.
4-189