TM 5-4320-275-13 & P
ACCUMULATOR (CONT)
LOCATION/ITEM
ACTION
REMARKS
INSPECTION
5. Accumulator
Inspect accumulator for thread damage and warp-
age. Replace if damaged or warped.
6. Pipe plug
Inspect for damaged threads. Replace if
damaged.
7. Nipple
Inspect for damaged threads and cracks. Replace
if damaged or cracked.
8. Seal plate and
Inspect for cracks and warpage. Replace if
check valve
damaged or warped.
assembly
CLEANING
WARNING
Clean parts in a well-ventilated area. Avoid inhalation of solvent fumes and prolonged
exposure of skin to cleaning solvent. Wash exposed skin thoroughly. Dry cleaning solvent
(fed spec P-D-680) used to clean parts is potentially dangerous to personnel and property. Do
not use near open flame or excessive heat. Flash point of solvent is 100 F (38C).
9. Accumulator,
Clean accumulator with cleaning solvent,
nipple, seal
P-D-680. Use a stiff-bristle brush to remove
plate, and check
caked dirt.
valve assembly
10. Pipe plug
Clean pipe plug with cleaning solvent,
P-D-680.
INSTALLATION
11. Accumulator
through screw holes in accumulator (8). Install
gasket (5) and seal plate (6) on cap screws (3).
Install check valve assembly (7) on cap screws
(3). Use Loctite on screw threads.
4-55