TM 5-3825-270-23&P
0198
REMOVAL - Continued
9.
Remove fitting (Figure 4, Item 21) from fitting (Figure 4, Item 22).
10.
Remove fitting (Figure 4, Item 22) from pump assembly (Figure 4, Item 5).
11.
Remove drain cock (Figure 5, Item 23) from pump assembly (Figure 5, Item 5).
5
23
Figure 5. Water Pump Assembly Removal.
END OF TASK
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
1.
Apply sealing compound to threads of drain cock (Figure 6, Item 23).