TM 5-3825-270-23&P
0071
REMOVAL - Continued
3
13
15
14
Figure 4. Water Pump and Housing Removal.
NOTE
Perform Step (8) if plug or fittings are damaged.
8.
Remove fitting (Figure 4, Item 14) and plug (Figure 4, Item 13) from water pump housing (Figure 4, Item 3).
END OF TASK
INSTALLATION
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. Keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately
with soap and water. Failure to comply may result in injury or death to personnel.
1.
Apply sealing compound to threads of plug (Figure 5, Item 13).