TM 5-3825-270-23&P
0069
Table 1. FIELD LEVEL PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
EQUIPMENT NOT
ITEM TO BE CHECKED
READY/
ITEM
INTERVAL
OR SERVICED
PROCEDURE
AVAILABLE IF:
NO.
that will impair
operation.
0.25 IN. MAX
(6.4 MM)
0.125 IN. MAX
(3.18 MM)
Figure 6. Hook Bar.
7
250 Hours/
Water Tank Mount
Check and re-torque the following
Semi-
Screws
water tank mount screws:
Annual
a. Re-torque 16 isolator mount
screws to 400 lb-ft (542 Nm).
screws to 220 lb-ft (298 Nm).