Figure 5. Cab Control Box Engine Speed Set Switch - Step 4.
Figure 8. Cab Control Box Engine Speed Set Switch - Step 6.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  350    351    352    353    354  355  356    357    358    359    360  
img
.
TM 5-3825-270-23&P
0062
UPIK AIR
CONNECTION
UPIK
ELECTRICAL
CONNECTION
Figure 6. UPIK Electrical Connection - Step 5.
2.
Ensure multimeter is set to measure continuity.
WARNING
Ensure electrical power is off prior to working on all electrical systems. Failure to comply
may result in injury or death to personnel.
Remove all jewelry, such as rings, ID tags, bracelets, etc., prior to working on or around
equipment. Jewelry and tools can catch on equipment, contact positive electrical circuits,
and cause a direct short, severe burns, or electrical shock. Failure to comply may result
in injury or death to personnel.
3.
Connect red multimeter lead to UPIK harness connector pin A.
UPIK HARNESS
PIN A
CONNECTOR
Figure 7. UPIK Harness Connector Pin A - Step 5.
4.
Connect black multimeter lead to a known good ground.
5.
Note multimeter reading.
CONDITION/INDICATION
Are less than 200 ohms measured at UPIK harness connector pin A to known good ground?
0062-5