Figure 9. Positive Terminal Strip - Step 5.
Figure 13. Water Level Low Indicator - Step 7.

Field Maintenance Manual Tools List For Engineer Mission Module - Water Distributor Page Navigation
  266    267    268    269    270  271  272    273    274    275    276  
img
.
TM 5-3825-270-23&P
0046
STEP 6
Are less than 200 ohms measured on green/white wire from low tank level switch harness connector to
WATER LEVEL LOW indicator?
1.
Ensure multimeter is set to measure continuity.
2.
Connect red multimeter probe to green/white wire at WATER LEVEL LOW indicator.
GREEN/WHITE
WIRE
BLACK
JUMPER
WIRES
WATER
LEVEL LOW
BACK OF
INDICATOR
CONTROL PANEL
Figure 11. Water Level Low Indicator - Step 6.
3.
With the aid of an assistant using jumper wire, connect black multimeter probe to black wire at low tank level
switch harness connector.
PIN 2
PIN 1
(BLACK WIRE)
(RED WIRE)
Figure 12. Low Tank Level Switch Harness Connector - Step 6.
4.
Note multimeter reading.
CONDITION/INDICATION
Are less than 200 ohms measured on green/white wire from low tank level switch harness connector to WATER
LEVEL LOW indicator?
0046-7