Table 1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
Figure 18. UPIK Interface Kit.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  267    268    269    270    271  272  273    274    275    276    277  
img
.
TM 5-3825-270-10
0071
Table 1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
EQUIPMENT NOT
ITEM TO BE CHECKED
READY/
ITEM
INTERVAL
OR SERVICED
PROCEDURE
AVAILABLE IF:
NO.
FITTING
CLAMPS
HOSE
FUEL TANK
FUEL GAUGE
FUEL CAP
CHAIN
FUEL CAP
Figure 17. Fuel Tank.
18
Before
UPIK Interface Kit
1. Check UPIK and the following
UPIK interface
hardware for presence and obvious
kit has damage
signs of damage:
that will impair
a. Cap
operation.
b. Air hose cap
c. Cap chain
d. Pins
e. Cable seal
0071-19