• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 13. Floating Strainer.
Figure 16. Water Level Indicator.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  264    265    266    267    268  269  270    271    272    273    274  
img
.
TM 5-3825-270-10
0071
Table 1. OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued
EQUIPMENT NOT
ITEM TO BE CHECKED
READY/
ITEM
INTERVAL
OR SERVICED
PROCEDURE
AVAILABLE IF:
NO.
VENT
Figure 14. Vent.
15
Before
Tank
1. Check the tank and welds for
Class III leak is
cracks, leaks, and obvious signs of
evident, tank
damage.
has cracks or
obvious dam-
age that will im-
pair operation.
TANK
Figure 15. Tank.
16
Before
Water Level Indicator
1. Check the following hardware for
Switch(es),
presence and obvious signs of
needle, gauge,
damage:
wiring or con-
0071-16