LOAD TANK AT STRAINER WITH SYSTEM PUMP AND 3" HOSE
Figure 4. Load Tank At Strainer With System Pump And Floating Strainer.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  99    100    101    102    103  104  105    106    107    108    109  
img
.
TM 5-3825-270-10
0020
LOAD TANK AT STRAINER WITH SYSTEM PUMP AND FLOATING STRAINER - Continued
3
4
Figure 2. Load Tank At Strainer With System Pump And Floating Strainer.
NOTE
Use of a single suction hose will allow faster loading if water depth and close positioning of
water distributor near water source is possible. Use both hoses when strainer must be placed
further out from edge of water source to find deeper water.
7.
Connect suction hose(s) (Figure 3, Item 3) to floating strainer (Figure 3, Item 1).
1
3
Figure 3. Load Tank At Strainer With System Pump And Floating Strainer.
8.
Remove cap (Figure 4, Item 5) from connection point C1 (Figure 4, Item 6).
0020-2