TM 5-3825-270-10
0018
CIRCULATE TANK WITH PUMP TO BLEND OR RINSE - Continued
6
5
10
9
8
7
Figure 4. Circulate Tank With Pump To Blend Or Rinse.
CAUTION
Release engine start/stop switch once engine is started. Failure to comply may result in
damage to equipment.
Do not let engine run more than 5 minutes without circulating water through pump. Failure
to comply may result in damage to equipment.
5.
Start engine by pressing up and holding the engine start/stop switch (Figure 4, Item 5) until engine is started.
6.
Adjust engine rpm (Figure 4, Item 6) by pressing up or down on the rpm switch (Figure 4, Item 8).
CAUTION
Ensure that engine speed is more than 1500 rpm. Failure to comply may result in damage to
equipment.
7.
When engine rpm (Figure 4, Item 6) is to desired setting press set switch (Figure 4, Item 7) to set rpm .
CAUTION
Engine speed must be at idle speed before engine is shut down. Failure to comply may result
in damage to equipment.
8.
When circulation procedure is complete, press RESUME/IDLE switch (Figure 4, Item 9) to the IDLE position
to return engine rpm (Figure 4, Item 6) to idle speed.
9.
Shut water distributor engine off by pressing down on start/stop switch (Figure 4, Item 5).
10.
Push in on emergency stop button (Figure 4, Item 10).