Figure 1. Connect UPIK to Prime Mover.
Figure 4. Connect UPIK to Prime Mover.

Technical Manual For Engineer Mission Module - Water Distributor Page Navigation
  41    42    43    44    45  46  47    48    49    50    51  
img
.
TM 5-3825-270-10
0012
CONNECT UPIK TO PRIME MOVER FROM PRIME MOVER - Continued
7
2
4, 5
Figure 2. Connect UPIK to Prime Mover.
CAUTION
UPIK harness is match marked for ease of connection. Ensure that UPIK harness is aligned
during connection. Failure to comply may cause damage to pins in harness.
7.
Connect UPIK harness connector (Figure 2, Item 5) to UPIK connection point (Figure 2, Item 4).
8.
Route UPIK harness (Figure 3, Item 9) through wire trough (Figure 3, Item 10).
9
10
Figure 3. Connect UPIK to Prime Mover.
9.
Route UPIK harness (Figure 4, Item 9) through front shackle (Figure 4, Item 11).
0012-2