Figure 16. Mud Pump Drain Plugs Removal.
Figure 18. Sand Guzzler Hose Disconnect.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  683    684    685    686    687  688  689    690    691    692    693  
img
.
TM 5-3820-276-10-2
0225
WINTERIZE MUD CLEANING SYSTEM (MCS) - Continued
7.
Disconnect 4-in. (102 mm) mud hose (Figure 17, Item 2) from mud pan (Figure 17, Item 3).
1
2
4
3
WWDS00080
Figure 17. Mud Hose Disconnect.
8.
Disconnect 4-in. (102 mm) mud hose (Figure 17, Item 2) from connector (Figure 17, Item 1) on side of MCS.
WARNING
Do not open or disconnect hydraulic hoses or fittings while the hydraulic oil is hot or under
pressure. Hydraulic oil is flammable and harmful to the skin and eyes. The hydraulic tanks
and metal parts can be hot. Wear work gloves and eye protection when handling hydraulic
hoses, motors, and hydraulic parts. If hydraulic oil contacts skin, wash the affected area
immediately. In case of eye contact, flush with water for 15 minutes. Dispose of hydraulic
oil in accordance with standard operating procedures. Failure to comply may result in injury
or death to personnel. Seek medical attention in the event of an injury.
9.
Disconnect case drain hose (Figure 17, Item 4) from sand guzzler case drain hose (Figure 17, Item 3).
0225-18