PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - WELDER/GENERATOR
Table 1. PMCS - Welder/Generator - Before Drilling Equipment Operation - Continued

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  486    487    488    489    490  491  492    493    494    495    496  
img
.
TM 5-3820-276-10-2
0202
Table 1.
PMCS - Welder/Generator - Before Drilling Equipment Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
NOTE
1
Before
Oil Change
Indicator/
Engine hours are shown on the
Maintenance
maintenance display for
Display
maintenance interval purposes, and
are retrieved with the engine off and
engine control switch in the RUN/
IDLE position.
Oil hours start at 100 and count
down to 0 (a flashing wrench icon
will appear indicating oil change is
due).
Negative hours indicate when past
recommended oil change interval.
Check oil change indicator/maintenance display
Engine hours exceeded,
(Figure 1, Item 3) with engine off and engine control
oil change is due. Notify
switch (Figure 1, Item 1) in RUN position to observe
maintenance.
hours before next oil change.
2
3
4
1
WWDS00423
Figure 1.
Fuel and Oil - Maintenance Display.
2
Before
Fuel Level
Check the fuel level on the fuel level indicator/
Fuel is below operating
Indicator/
maintenance display (Figure 1, Item 2), or fuel sight
level.
0202-2
02/13/2013root(pmcswp)wpno(I20002)