Figure 20. Cooling System Service.
Figure 22. Portable Fire Extinguisher.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  362    363    364    365    366  367  368    369    370    371    372  
img
.
TM 5-3820-276-10-2
0198
Table 1.
PMCS - WWDR - Before Road and Towing Operation - Continued.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
1
2
WWDS00599
Figure 21. Alternator and A/C Belts.
2. Check A/C belts (Figure 21, Item 2) for cracking,
A/C belt cracked, frayed,
fraying, and broken pieces.
or broken. Notify
maintenance.
3. Close catwalks (Volume 1, WP 0029).
45
Before
Derrick
Check derrick hoses and fittings for damage and leaks. Derrick hoses or fittings
damaged or leaking.
Notify maintenance.
46
Before
Jib and Sandline
Check jib and sandline cables and hooks for damage.
Jib or sandline cables or
Cables and
hooks damaged. Notify
Hooks
maintenance.
47
Before
Fire Extinguisher 1. Check fire extinguisher safety pin (Figure 22, Item 1) Safety pin missing or seal
and seal for security.
broken. Notify
maintenance.