ENGINE DOES NOT CRANK - GROUTER - Continued
Figure 1. THROTTLE CONTROL Switch.

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  179    180    181    182    183  184  185    186    187    188    189  
img
. . . .
TM 5-3820-276-10-2
0142
OPERATOR MAINTENANCE
ENGINE STARTS BUT RUNS IRREGULARLY OR FAILS - GROUTER
INITIAL SETUP:
References
Equipment Condition
Volume 1, WP 0038
Engine off (Volume 1, WP 0040)
WP 0203
WP 0209
WP 0211
TROUBLESHOOTING PROCEDURE
ENGINE STARTS BUT RUNS IRREGULARLY OR FAILS - GROUTER
SYMPTOM
Engine RPM at idle and/or under load fluctuates, or engine stalls.
MALFUNCTION
Engine RPM set too low.
CORRECTIVE ACTION
NOTE
Under load, increased RPM may be required to maintain proper and smooth
engine operation.
1.
Start engine (Volume 1, WP 0040).
2.
Using THROTTLE CONTROL switch, raise RPM and verify if engine operation returns to
normal (Volume 1, WP 0040) (Figure 1).
0142-1