TM 5-3820-276-10-2
0132
HYDRAULIC FUNCTIONS DO NOT OPERATE - WWSV - Continued
CORRECTIVE ACTION - Continued
MALFUNCTION
Hydraulic oil cold or hot.
CORRECTIVE ACTION
NOTE
Hydraulic functions may be sluggish and/or not operate properly until fluid has
reached correct operating temperature.
1.
Start engine (Volume 1, WP 0012) and engage P.T.O. (Volume 1, WP 0032).
2.
Run engine and wait to use hydraulic functions until hydraulic oil sight/temperature gauge
( Figure 1) reads a minimum of 75F (24C) (Volume 1, WP 0032).
HYDRAULIC OIL
SIGHT/TEMPERATURE
GAUGE
WWDS00616
Figure 1.
Hydraulic Oil Sight/Temperature Gauge.
a.
If hydraulic functions operate, problem solved.
b.
If hydraulic functions do not operate, notify maintenance.
c.
If hydraulic oil temperature is above 180F (82C), proceed to Hydraulic Oil Temperature
High - Water Well Support Vehicle (WWSV) (WP 0133).
END OF WORK PACKAGE