Figure 5. Ignition Switch
Figure 2. Ignition Switch

Technical Manual For Water Well Drilling System (Wwds) - 2 Page Navigation
  1    2    3    4    5  6  7    8    9    10    11  
img
. . . .
TM 5-3820-276-10-2
0085
OPERATOR MAINTENANCE
ENGINE CRANKS BUT DOES NOT START - WATER WELL DRILLING RIG (WWDR)
INITIAL SETUP:
References
Equipment Condition
Volume 1, WP 0014
Engine off (Volume 1, WP 0012)
Volume 1, WP 0017
Volume 1, WP 0066
WP 0109
WP 0198
TROUBLESHOOTING PROCEDURE
ENGINE CRANKS BUT DOES NOT START - WWDR
SYMPTOM
Engine attempts to start but does not start.
MALFUNCTION
ENGINE STOP switch enabled.
CORRECTIVE ACTION
Verify if ENGINE STOP switch is pushed in (Figure 1).
ENGINE
STOP
SWITCH
WWDS00479
Figure 1.
ENGINE STOP Switch.
a.
If ENGINE STOP switch is pushed in, pull switch out.
b.
If ENGINE STOP switch is not pushed in, proceed to next MALFUNCTION - Indicated fuel
level low.