UNIT TROUBLESHOOTING PROCEDURES
TROUBLESHOOTING PROCEDURE (Cont) - TM-10-5430-245-13-P0053
TM-10-5430-245-13-P Drum Fabric Collapsible Drinking Water 500 Gallon Capacity Model GTA500W (NSN 5430-01-527-4514) Manual
Page Navigation
24
25
26
27
28
29
30
31
32
33
34
TM
10-5430-245-13&P
0009
00
STEP
2. If
leakage
continues,
remove
coupler
valve
(Figure
1,
Item
1)
from
adapter
assembly
(Figure
1,
Item
2).
If
water
is
leaking
from
adapter
assembly
(Figure
1,
Item
2),
replace
adapter
assembly
(WP
0016).
1
2
3
LEAK
Figure 1.
STEP
3. If
adapter
assembly
(Figure
1,
Item
2) is
not
leaking,
replace
gasket
(Figure
1,
Item
3)
(WP
0015)
on
coupler
valve
(Figure
1,
Item
1).
Reinstall
coupler
valve
(Figure
1,
Item
1)
onto
adapter
assembly
(Figure
1,
Item
2).
STEP
4. If
leakage
continues,
replace
coupler
valve
(Figure
1,
Item
1)
(WP
0012)
.
MALFUNCTION
Coupler
valve
(Figure
2,
Item
1)
leaks
at
valve
outlet.
CORRECTIVE
ACTION
Replace
coupler
valve
(Figure
2,
Item
1)
(WP
0012).
0009