TROUBLESHOOTING PROCEDURE - TM-10-5430-245-13-P0044
TROUBLESHOOTING PROCEDURE (Cont) - TM-10-5430-245-13-P0046
TM-10-5430-245-13-P Drum Fabric Collapsible Drinking Water 500 Gallon Capacity Model GTA500W (NSN 5430-01-527-4514) Manual
Page Navigation
19
20
21
22
23
24
25
26
27
28
29
TM
10-5430-245-1
3&P
0008
00
CORRECTIVE
ACTION
If
cam
arm
assemblies
(Figure
2,
Item
1)
are
worn,
replace
coupler
valve
(WP
0012).
SYMPTOM
Water
is
leaking
from
around
coupler
valve
(Figure
3,
Item
1).
MALFUNCTION
Water
leaks
from
coupler
valve
(Figure
3,
Item
1) to
adapter
assembly
(Figure
3,
Item
2).
CORRECTIVE
ACTION
a. Make
sure
coupler
valve
(Figure
3,
Item
1) is
properly
closed,
locked
and
installed
in
place.
b. If
leakage
continues,
remove
coupler
valve
(Figure
3,
Item
1)
from
adapter
assembly
(Figure
3,
Item
2).
c. If
water
is
leaking
from
adapter
assembly
(Figure
3,
Item
2),
notify
Unit
Maintenance.
d. If
adapter
assembly
(Figure
3,
Item
2) is
not
leaking,
check
gaskets
in
coupler
valve
(Figure
3,
Item
1)
for
damage
or
contamination
.
Notify
Unit
Maintenance
if
gasket
is
damaged
or
contaminated.
Reinstall
coupler
valve
(Figure
3,
Item
1)
and
lock
back
in
place.
e. If
leakage
continues,
replace
coupler
valve
(Figure
3,
Item
1)
(WP
0012).