TM 10-4930-204-13(2) If cable or switch is damaged, replace cable assembly.(3) Remove connector from J1 receptacle. Clean connectors to obtain a good connection at J1 connector atJunction Box. If connector is damaged, notify Organizational Maintenance for replacement.Figure 3-4.1. Pump Assembly Cables.3-9. FILTER/SEPARATOR SERVICE.Refer to figure 3-5 for procedures to service the filter/separator.3-10. TANK, LIFTING EYE, DRAG LOOPS AND GASKETS.a.Inspect the fuel tanks, lifting eyes, drag loops, and gaskets for any damage or defects.b. Report any damaged or defective part to organizational maintenance for replacement and to direct supportmaintenance for repairs.3-14