12. Strip 6-in of outer insulation off of wire (figure 12, item 1).
13. Cut and strip new wire to same length as wires removed (figure 12, item 1).
14. Strip 3/8-in insulation off individual wires (figure 12, item 1).
15. Feed new wire through strain relief nut (figure 13, item 1) and grommet (figure 13, item 2) into J-Box.
16. Crimp ring terminals on wires (figure 12, item 4).
17. Install ring terminal on connection post (figure 13, item 3).
18. Fasten ring terminal with mounting nuts.
19. Tighten strain relief nut (figure 13, item 1).
20. Install cover (figure 13, item 4) on J-Box (figure 13, item 5).
4
2
1
3
Figure 12. Wire Insulation
0036 00-9