TM 10-4320-344-24
PROCEDURES:
1 .
Refer to appendix F, Figure F-2, and using a multimeter, determine which
w i r e i s d e f e c t i v e.
2.
If defective wire is soldered, desolder wire from connector.
3.
Remove defective wire from wiring harness.
4.
Refer to table D-4 and cut wire from bulk. Wire assembly numbers in table
D-4 are for information only, they are not marked on wiring harness, refer
to terminations to determine what components comprise damaged wire.
5.
Strip approximately 0.250 (0.635 cm) inch of insulation from each end of
w i r e .
6.
Crimp or solder terminal(s) to wire.
7 .
For all soldered assemblies install heat-shrink tubing over solder
connections.
a.
For all wire assembly numbers in table D-5, noted with a 1 use heat-
shrink tubing 18763-245.
b .
For all wire assembly numbers in table D-5, noted with a 2 use heat-
shrink tubing part number 18763-244.
8.
Install repaired wire in wiring harness.
Table D-4. Parts List for Control Panel Wiring Harness Assembly, Model 609-C.
Find
Part or
Quantity
Description
NSN
Number
Identifying Number
Required
1
27228-505
4
Connector, Pin
2
27214-514
6
Terminal
3
27214-513
18
Terminal
4
27214-515
4
Terminal
5
27214-505
1
Terminal
6
S-1790
2
Connector
7
27214-504
1
Terminal
8
27214-503
1
Terminal
9
27228-515
8
Connector, Socket
10
27284-202
1
Splice, Wire
11
S-1950
1
Assembly, Connector
12
27215-312
11
Terminal
13
27215-321
1
Terminal
14
27215-302
3
Terminal
15
18142-421
AR
Wire, Cable,
E l e c t r i c al
16
18142-411
AR
Wire, Cable,
E l e c t r i c al
17
18763-245
AR
Tubing, Heat-Shrink
18
18763-244
AR
Tubing, Heat-Shrink
D-6