TM 10-4320-344-24
Figure 3-35.
Rocker Arm Assembly Removal, Model 609-A.
3.8.17.2 Disassembly.
a.
b.
c .
d.
To prevent accidental disassembly, carefully remove holding wire from rocker
arm assembly.
Tension on spacing springs will be released when wire is
removed.
Remove holding wire from rocker arm assembly (3).
Carefully remove two rocker arm shafts (Figure 3-36, 1) from center shaft
support (2).
To make reassembly of rocker arm shafts easier, tag and lay out
parts in the order removed.
Slide following parts from each rocker arm shaft (1):
1 center spacer (3)
6 rocker arms (4)
3 shaft springs (5)
1 1 s p a c e r s ( 6)
3 shaft supports (7)
Remove retaining ring (8) and plug (9) from end of each rocker arm shaft (1).
3-83
NOTE