TM 10-4320-344-24
3.8.8 Governor Maintenance. Model US636HCCD-1.
This task covers:
3.8.8.1 Removal
3 .8 . 8 . 3 I n s t a l l a t i o n
3 .8 . 8 . 2 R e p a ir
3.8.8.4 Calibration and Adjustment
INITIAL SETUP
Tools
General Mechanics Automotive
Tool Kit, Appendix B, Section
III, Item 1
Multimeter, Appendix B, Section III,
Item 2
Vernier Calipers, Appendix B, Section
III, Item 3
Material/Parts
Tags, Appendix C, Item 31
Lock Washers (TM 10-4320-344-24P)
Equipment Conditions
Pumping station shut down, TM
10-4320-344-10.
Equipment Conditions
(Continued)
Battery disconnected, paragraph 2.15.5.
Control Panel Cover Assembly removed,
paragraph 2.16.2 (for calibration and
adjustment only).
General Safety Instructions
Do not work on equipment that is not
securely stabilized to prevent rolling
o r s l i d i n g.
Do not work on equipment with battery
connected. Electrocution hazard is pres-
ent if battery is present.
Do not work on equipment without follow-
ing standard shop safety practices.
3.8.8.1 Removal.
Figure 3-23.
Governor Maintenance, Model US636HCCD-1.
3-55