3.6.10 Pump Mount Isolators Replacement, Model 609-C.
This task covers:
3.6.10.1
Removal
3 .
6 .1 0 . 2 I n s t a l l a t i o n
Tools
Equipment Conditions (Continued)
General Mechanics Automotive
Pumping assembly removed, paragraph 3.6.1.
Tool Kit, Appendix B, Section III,
Item 1
General Safety Instructions
Materials/Parts
Do not work on equipment that is not
securely stabilized to prevent rolling
Lock Washers (TM 10-4320-344-24P)
o r s l i d i n g.
Equipment Conditions
Do not work on equipment without follow-
ing standard shop safety practices.
Pumping station shut down, TM 10-4320-
344-10.
3.6.10.1
and two
3.6.10.2
Removal.
Remove four nuts (Figure 3-13, 1), lock washers (2), cap screws (3)
pump mount isolators (4).
Discard lock washers (2).
Installation.
with four cap screws
Figure 3-13. Pump Mount Isolators.
Position two pump mount isolators (4) on
(3), new lock washers (2), and nuts (1).
trailer (5) and secure
3-33