TM 10-4320-34-24
Do not work on equipment with battery connected. Electrocution hazard is
present if battery is connected. Failure to obey this warning may result in
serious personal injury.
a .
Loosen twenty screws (Figure 2-90, 1) and tag and disconnect twenty wires (2).
b .
Remove four nuts (3) and screws (4).
c .
Remove terminal board (5) from control panel (6).
2.16.34.3 Installation.
a.
Position terminal board (5) on control panel (6) and secure with four screws
(4) and nuts (3).
b.
Refer to tags and connect twenty wires (2) on terminal board (5) securing with
twenty screws (1).
Remove and discard tags.
2-221