TM 10-4320-344-10
Table 2-12.
Preventive Maintenance Checks and Services for Pumping Assembly
Model US636HCCD-1.
(Continued)
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable if:
BATTERY BOX
20
21
Fumes from battery acid may cause explosion,
which could result in
personal injury.
Keep sparks and open flame away from battery.
Battery electrolyte contains sulfuric acid, which can cause severe burns.
Handle batteries with care.
If electrolyte should contact skin or
c l o t h i n g,
rinse immediately with clean water.
Before
Before
Battery Box and
Cover
Battery and
Battery Cables
Check for damage.
If damaged,
notify unit maintenance.
Remove cover.
Check cables
for corrosion, loose
connections, and damage.
Clean corrosion and tighten
connections as required.
Check battery for cracks.
Remove battery caps and check
f l u i d l e v e l.
Notify unit
maintenance if fluid level is
low .
Install battery caps and
battery box cover.
Cracked battery.
Low fluid level.
Damaged battery
cables .
2-72