TM 10-4320-344-10Table 2-12.Preventive Maintenance Checks and Services for Pumping AssemblyModel US636HCCD-1.(Continued)LocationItemItem toNot Fully MissionNo.IntervalCheck/ServiceProcedureCapable if:FUELTANK33Hot refueling of pumping assembly while it is operating poses a safety hazardand should not be attempted.Hot engine surfaces and sparks produced from theengine and control circuitry are possible sources of ignition.Severepersonal injury or death and/or damage to the equipment may result.DuringFuel Tank andGaugeCheck fuel tank for cracks,damage, or leaks.Check fuellevel indication on fuelgauge.If fuel is required,remove fuel tank cap and addf u e l.Install cap afteradding fuel.C l a s s I , I I , orIII leak.Cracked ordamaged fueltank.2-77