TM 10-4320-344-10
Table 2-11.
Preventive Maintenance Checks and Services for Pumping Assembly
Model 609-C.
(Continued)
Item
No.
Not Fully Mis-
Procedure
sion Capable if:
BATTERY BOX
21
22
Fumes from battery acid may cause explosion, which could result in
personal injury.
Keep sparks and open flame away from battery.
Battery electrolyte contains sulfuric acid, which can cause severe burns.
Handle batteries with care.
If electrolyte should contact skin or
clothing, rinse immediately with clean water.
Before
Before
Battery Box
Batteries and
Battery Cables
Check for damage.
If damaged,
notify unit maintenance.
Unlatch and open battery box
cover.
Check cables for
corrosion, loose connections,
and damage.
Clean corrosion
and tighten connections as
required.
Check battery for
cracks or damage.
Remove
battery caps and check fluid
l e v e l .
If fluid level is low,
notify unit maintenance.
Install battery caps.
Close
and latch battery box cover.
Cracked battery.
Low fluid level.
Damaged battery
c a b l e.
2-50
Interval
L o c a t i on
I t e m t o
Check/Service