Troubleshooting Chart
SYMPTOM
POSSIBLE CAUSE(S)
CORRECTIVE ACTION
Pump will not prime or retain
1. Air leak in suction line
1. Repair or replace.
prime after operating
2. Suction line inlet above liquid
2. Submerge suction line in liquid.
level
Pump will not start or run
1. Improperly wired
1. Check voltage supply outlet and
rewire motor connections,
if necessary.
2. Blown fuse or open circuit
2. Replace fuse or close circuit
breaker
breaker.
3. Loose, broken, or incorrect
3. Rewire any incorrect circuits.
wiring
Tighten connections, replace
defective wires.
4. Defective pressure switch
4. Adjust switch setting. Clean
contacts with emery cloth, if
dirty. Replace if necessary.
5. Piping to pressure switch plugged
5. Clean or replace piping.
6. Motor shorted out
6. Replace motor.
Pump runs, but no fluid
1. Faulty suction piping
1. Replace.
2. Pump located too far from fluid
2. Relocate.
3. Gate valve closed
3. Open.
4. Clogged strainer
4. Clean or replace.
5. Fouled foot valve
5. Clean or replace
6. Suction line inlet above liquid
6. Submerge suction line in liquid.
level
Liquid drips from point where
Damaged mechanical seal
Replace.
shaft enters the pump housing,
(See MECHANICAL SEAL
when pump is full of liquid
REPLACEMENT)
Pump starts and stops too often
1. Faulty pressure switch
1. Repair or replace
2. Leak in suction valve
2. Repair.
3. Leak in foot-valve
3. Repair or replace.
Excessive noise while pump is in
1. Pump not secured to firm
1. Secure properly.
Operation
foundation
2. Piping not supported to relieve
2. Make necessary adjustments.
any strain on pump assembly
3. Motor improperly connected.
3. Rewire electrical connections.