TM 10-4320-321-13&PFORM 5S2583MODELS 2P121 THRU 2P128 & WP373 THRU 2P38001615Troubleshooting ChartSYMPTOMPOSSIBLE CAUSE(S)CORRECTIVE ACTIONPump will not prime or retain1. Air leak in suction line1. Repair or replace.prime after operating2. Suction line inlet above liquid2. Submerge suction line in liquid.levelPump will not start or run1. Improperly wired1. Check voltage supply outlet andrewire motor connections,if necessary.2. Blown fuse or open circuit2. Replace fuse or close circuitbreakerbreaker.3. Loose, broken, or incorrect3. Rewire any incorrect circuits.wiringTighten connections, replacedefective wires.4. Defective pressure switch4. Adjust switch setting. Cleancontacts with emery cloth, ifdirty. Replace if necessary.5. Piping to pressure switch plugged5. Clean or replace piping.6. Motor shorted out6. Replace motor.Pump runs, but no fluid1. Faulty suction piping1. Replace.2. Pump located too far from fluid2. Relocate.3. Gate valve closed3. Open.4. Clogged strainer4. Clean or replace.5. Fouled foot valve5. Clean or replace6. Suction line inlet above liquid6. Submerge suction line in liquid.levelLiquid drips from point whereDamaged mechanical sealReplace.shaft enters the pump housing,(See MECHANICAL SEALwhen pump is full of liquidREPLACEMENT)Pump starts and stops too often1. Faulty pressure switch1. Repair or replace2. Leak in suction valve2. Repair.3. Leak in foot-valve3. Repair or replace.Excessive noise while pump is in1. Pump not secured to firm1. Secure properly.Operationfoundation2. Piping not supported to relieve2. Make necessary adjustments.any strain on pump assembly3. Motor improperly connected.3. Rewire electrical connections.-8-