TM 10-4320-315-10
CAUTION
The pump is self-priming after initial priming. If pump does not prime within 3 minutes,
overheating and damage to seals may occur.
(11) Check pump suction and discharge pressures. Shut down engine if pump does not prime within 3 minutes
Refer to troubleshooting
f.
Automatic Mode Operation (Shutdown. Pump Steed Control). Perform the following (Figure 2-7):
(1)
Turn AUTO THROTTLE (9) to START position.
CAUTION
Engine is air cooled and turbocharger is hot from exhaust gases. Engine should not be
shutdown suddenly from full-load running or damage may occur.
(2)
Idle engine 2 to 3 minutes to allow for temperature balance.
(3)
Set ENGINE SWITCH (3) to OFF
(4)
Set ELECTRICAL SWITCH (12) to OFF.
(5)
Depress red button (4) to unlock MANUAL THROTTLE (5) and turn MANUAL THROTTLE knob (6) in to idle
position.
(6)
Close pump suction and discharge valves.
(7)
Close control panel door and air exhaust door.
(8)
Perform after (A) PMCS.
2-9.
Operation of Auxiliary Equipment. Not applicable.
2-10.
Preparation for Movement. Perform the following:
a.
Disconnect System. Disconnect pump suction and discharge lines system.
b.
Prepare Pumping Assembly. Perform the following (Figure 2-8):
(1)
Remove pump drain cap (9) and allow pump to drain.
(2)
When all water has drained from pump, reinstall drain cap (9).
(3)
Install protective covers on pump suction and discharge ports (7 and 8).
2-27