TM 10-4320-315-10
CAUTION
DO NOT operate pump unless casing is filled to level of suction port. Operating a dry pump
will cause overheating and damage to pump unit.
e.
Make sure drain valves (Figure 2-2) on inside of control panel are closed.
Figure 2-2. Control Panel Drain Valves
f.
Remove priming line cap and prime pump with potable water (approximately 7 gallons (26.5 1)).
g.
Install the priming line cap and open pump suction and discharge valves
WARNING
DO NOT operate engine around open fuel Fuel presents an extreme explosion and fire
hazard. Make sure fuel lines are securely connected and free of leaks. Avoid overfilling fuel
tank.
CAUTION
Always use correct fuel type
h.
If engine is to be operated from external fuel supply, perform the following (Figure 2-3):
(1)
Connect fuel supply hose (4) from auxiliary fuel tank to AUXILIARY FUEL INLET connector (5)
(2)
Connect fuel return hose (3) from auxiliary fuel tank to AUXILIARY FUEL RETURN connector (2).
(3)
Move fuel selector valve (6) to AUXILIARY ON LINE position.
(4)
Move fuel return valve (1) to AUXILIARY LINE RETURN position.
2-19